Automated Equipment Common Fault Detection
Nov 02, 2018

Any automation equipment consists of three parts: the actuator, the sensor part, and the controller part. When the automation equipment suddenly fails and does not work, or the work sequence is abnormal, it must be diagnosed. Below we take a look at the three parts of the device to understand the method of diagnostic automation equipment failure


1. Check all power, air and hydraulic sources of the automation machine.

Problems with power, air and hydraulic sources can often cause automation equipment to fail. For example, there is a problem with the power supply, including the power supply failure of the entire workshop, such as low power supply, burned out of the insurance, poor contact of the power plug, etc.; the air pump or hydraulic pump is not turned on, the pneumatic triple or the two-piece is not opened, and the relief valve in the hydraulic system Or some pressure valves are not open, etc. The following aspects should be included when testing automation equipment:


The power supply includes the power supply for each device and the power of the workshop.

Air source, including the air pressure source required for pneumatic equipment.

Hydraulic sources, including the operation of hydraulic pumps required for automated equipment hydraulics.

2. Check if the sensor position of the automation device is offset.

Due to the negligence of equipment maintenance personnel, there may be errors in the position of some sensors, such as no in place, sensor failure, sensitivity failure, etc. Always check the sensor's sensing position and sensitivity, and adjust the deviation in time. If the sensor is broken, replace it immediately. Many times, in addition, due to the vibration of the automation equipment, most of the sensors will be loose after a long period of use, so in the routine maintenance, always check whether the sensor is in the correct position and is firmly fixed.

3, check the relay of the automation equipment, flow control valve, pressure control valve

Like the magnetic inductive sensor, the relay can also be stuck in the long-term use, which cannot guarantee the normality of the electrical circuit and needs to be replaced. In pneumatic or hydraulic systems, the throttle opening and the pressure regulating spring of the pressure valve may also loosen or slide as the device vibrates. These devices, like sensors, are components that require routine maintenance in automated equipment.

4, check electrical, pneumatic and hydraulic circuit connections

If no problems are found in the above three steps, then all circuits are checked. Check if there is any open circuit in the circuit, especially if the wire in the wire slot is broken by the wire slot. Inspect the air tube for damaging creases. Check if the hydraulic hose is clogged. If the trachea has a serious crease, replace it immediately. The hydraulic tubing should be replaced.